Home > Failed To > Symantec Endpoint Protection Manager Failed To Connect To The Server Make Sure

Symantec Endpoint Protection Manager Failed To Connect To The Server Make Sure

Contents

OR If the Symantec Endpoint Protection Manager service fails to start then run Management Server Configuration Wizard in order to log in to the Symantec Endpoint Protection Manager. No Yes logo-symantec-dark-source Loading Your Community Experience Symantec Connect You will need to enable Javascript in your browser to access this site. © 2016 Products Products Home Threat Protection Advanced Threat Provide feedback on this article Request Assistance Print Article Products Subscribe to this Article Manage your Subscriptions Search Again Situation The Symantec Endpoint Protection Manager (SEPM) login process bar hang for Verify that the server name and port are correct." Symptoms This error has more than one potential cause: The name/port entered into the console are incorrect. have a peek at this web-site

Force the recreation of sem5.log. The name entered into the console is not able to be resolved to the correct computer. The SEPM console itself cannot connect to the Database. Java version 1.4 and earlier are not supported and will need to be upgraded.

Symantec Endpoint Protection Manager Failed To Connect To The Server Make Sure

Translated Content This is machine translated content Login to Subscribe Please login to set up your subscription. No Yes logo-symantec-dark-source Loading Your Community Experience Symantec Connect You will need to enable Javascript in your browser to access this site. © 2016 logo-symantec-dark-source Loading Your Community Experience Symantec Connect Fatal error: Could not open/read file: C:\Program Files\Symantec\Symantec Endpoint Protection Manager\data\inbox\log\traffic\4F9B3F56C8C8010801CC5461C422B1F4.tmp.dat Cause This issue is possibly caused by the SEPM unexpectedly shutting down while processing traffic logs, and being unable to Multiple entries in the err.log under C:\Program Files\Symantec\Symantec Endpoint Protection Manager\db folder: "07/06 16:53:26.

This will change directories to the folder containing dbsrv9.exe. If not, fix the name resolution issues on the network or enter in the manager IP address instead. Version 11.x Stop SymantecEmbeddedDatabase and Symantec Endpoint Protection Managerservices in the Services.MSC Rename sem5.log to sem5.log.old For 32 Bit: "C:\Program Files\Symantec\Symantec Endpoint Protection Manager\db\" For 64 Bit: "C:\Program Files (x86)\Symantec\Symantec Endpoint The Java Virtual Machine Exited With A Code Of 1 TECH134782 March 8th, 2016 http://www.symantec.com/docs/TECH134782 Support / Error when logging to Symantec Endpoint Protection Manager: "Failed to connect to server".

If it staysstartedthen go ahead and log into theSymantec Endpoint Protection Managerand everything should now be working properly. If not, reference the following document for further troubleshooting: http://www.symantec.com/business/support/index?page=content&id=TECH102413&locale=en_US References "Which communication ports does the Symantec Endpoint Protection Manager 11.x use?" http://www.symantec.com/business/support/index?page=content&id=TECH102416&locale=en_US This document is available in the following Provide feedback on this article Request Assistance Print Article Products Subscribe to this Article Manage your Subscriptions Search Again Situation Why is logging into Symantec Endpoint Protection Manager producing the error: https://www.symantec.com/connect/forums/failed-connect-server-make-sure-server-running-and-your-session-has-not-timed-out Applies ToSymantec Endpoint Protection 11.1.x or 12.1.x Legacy ID 2010070815342348 Terms of use for this information are found in Legal Notices.

ClickStart, click onRunand Type “Services.MSC” then clickOKand start theSymantecEmbedded DatabaseService Start theSymantec Endpoint Protection Managerservice. Try these resources. If it stays started then go ahead and log into the Symantec Endpoint Protection Manager and everything should now be working properly. Error: "Failed to connect to the server, Verify that server name and port are correct".

Sepm Unexpected Server Error

Supported Products A-Z Get support for your product, with downloads, knowledge base articles, documentation, and more. OR If theSymantec Endpoint Protection Managerservice fails to start then runManagement Server Configuration Wizardin order to log in to theSymantec Endpoint Protection Manager. Symantec Endpoint Protection Manager Failed To Connect To The Server Make Sure Legacy ID 2007103013541248 Terms of use for this information are found in Legal Notices. Symantec Endpoint Protection Manager Service Not Starting java version 1.5 and later are supported for the Remote Console.

Some services stop automatically if they have no work to do, for example, the Performance Logs and Alerts service". http://technologyprometheus.com/failed-to/failed-to-connect-to-server-ragnarok-private-server.html Edit Conf.properties: Add scm.db.datasource=jdbc/metadatabaseto the last lineApplies ToSymantec Endpoint Protection 12.1.x Windows 2008 SQL Server 2005/2008 Terms of use for this information are found in Legal Notices. Server is not configured correctly Solution 1. Try to start the Symantec Endpoint Protection Manager service in Service Control Manager. Symantec Failed To Connect To The Server

Supported Products A-Z Get support for your product, with downloads, knowledge base articles, documentation, and more. Solution The following steps have been shown to resolve this issue, depending on the version of SymantecEndpoint Protection Manager installed. For 32 Bit, type: dbsrv11 -f"C:\Program Files\Symantec\Symantec Endpoint Protection Manager\db\sem5.db" For 64 Bit, type: dbsrv11 -f"C:\Program Files (x86)\Symantec\Symantec Endpoint Protection Manager\db\sem5.db" and pressEnter. Source For 32 Bit, type: dbsrv12 -f"C:\Program Files\Symantec\Symantec Endpoint Protection Manager\db\sem5.db" For 64 Bit, type: dbsrv12 -f"C:\Program Files (x86)\Symantec\Symantec Endpoint Protection Manager\db\sem5.db" and pressEnter.

Supported Products A-Z Get support for your product, with downloads, knowledge base articles, documentation, and more. Version 12.1.1xxx: Stop SymantecEmbeddedDatabase and Symantec Endpoint Protection Managerservices in the Services.MSC. Submit a False Positive Report a suspected erroneous detection (false positive).

Information for: Enterprise Small Business Consumer (Norton) Partners Our Offerings: Products Products A-Z Services Solutions Connect with us: Support

Did this article resolve your issue?

Browse to conf.properties by navigating through: %Program Files%\Symantec\Symantec Endpoint Protection Manager\tomcat\etc\conf.properties b. Education Services Maximize your product competency and validate technical knowledge to gain the most benefit from your IT investments. Create a SymAccount now!' Unable to Logon to Symantec Endpoint Protection Manager. Thank you for your feedback!

However, for compatibility with 1.6, the SEPM must be RU6 or later. Verify that the network can properly resolve the name of the computer running the manager. SEPM login process bar hang for a while, then error "Failed to connect to Server" pop up 2. "Symantec Endpoint Protection Manager" service crashes with a Java -1 error recorded in http://technologyprometheus.com/failed-to/synergy-failed-to-connect-to-server-server-refused-client-with-our-name.html Error 1.

OR If theSymantec Endpoint Protection Managerservice fails to start then runManagement Server Configuration Wizardin order to log in to theSymantec Endpoint Protection Manager. Close Login Didn't find the article you were looking for? Close Login Didn't find the article you were looking for? If all above steps fail toresolve the issue, repair and re-deploy the SEPM.

Thank you for your feedback! Submit a False Positive Report a suspected erroneous detection (false positive).

Information for: Enterprise Small Business Consumer (Norton) Partners Our Offerings: Products Products A-Z Services Solutions Connect with us: Support The Symantec Endpoint Protection Manager service is not started. Don't have a SymAccount?

This will change directories to the folder containingdbsrv11.exe. Don't have a SymAccount? Try these resources. Error: "Failed to connect to the server, Verify that server name and port are correct".

Submit a False Positive Report a suspected erroneous detection (false positive).

Information for: Enterprise Small Business Consumer (Norton) Partners Our Offerings: Products Products A-Z Services Solutions Connect with us: Support Solution Solutions provided as per cause: Verify the correct server name/port entered into the console and try again. If SQL Server DB used, restart the SQL Management service 3. Unable to start the embedded database service.

logo-symantec-dark-source Loading Your Community Experience Symantec Connect You will need to enable Javascript in your browser to access this site. © 2016 Products Products Home Threat Protection Advanced Threat Protection Endpoint